• bwin·必赢(中国)唯一官方网站

    Overview

    The GSC series SVG (Static Var Generator) by SIFANG. is a cutting-edge dynamic reactive power compensation device. The core of the system utilizes a mature cascaded structure from the power electronics converter domain. Each phase consists of multiple compact and standardized power units connected in series. Built on the company’s unified software and hardware control platform—proven in over ten thousand successful applications—the GSC series SVG delivers exceptional functionality, outstanding performance, and advanced control strategies. The GSC series SVG effectively mitigates voltage fluctuations, power factor instability, and harmonic distortions caused by the intermittent nature of wind and solar power generation, ensuring grid compliance and system reliability.

    Features

    Safe and Stable

    • Strong LVRT & HVRT capability
    • Rapid response to grid faults

    Powerful Functionality

    • Supports multiple compensation modes
    • Features low-frequency oscillation suppression
    • Dynamic response ≤ 1ms

    Compact and Reliable

    • Integrated controller design features
    • Minimal control delay
    • Strong electromagnetic interference resistance
    • Containerized compact design

    Excellent Scalability

    • Supports coordinated parallel operation of up to 16 SVG units

    Benefits

    Reactive Power Compensation

    Deliver fast, continuous, and dynamic inductive and capacitive reactive power to the power system, ensuring optimal grid performance and stability.

    Suppress Voltage Deviation and Fluctuation

    Maintain the stability of line and load-side voltages, suppressing voltage fluctuations and flicker.

    Reduce Line Losses

    Compensate for reactive power, improves power factor, and reduces line losses, enhancing overall system efficiency.

    Suppress Voltage Unbalance

    Eliminate negative sequence currents and suppresses three-phase imbalance, ensuring balanced and stable system operation.

    Harmonic Compensation

    Dynamic harmonic compensation, improving power quality and ensuring cleaner, more stable electrical supply.

    Typical Cases

    State Grid Xinjiang Kashgar Power Supply Company Taxian 220kV Substation Construction

    This project installs a ±15Mvar direct-connected dynamic reactive power compensation STATCOM system under the 35kV bus. Each unit enables continuous and rapid reactive power adjustment within a -15Mvar (inductive) to +15Mvar (capacitive) range. The SVG is connected to the 35kV system via reactors and meets technical requirements for reactive power control, voltage regulation, and power factor improvement.